Downloads provided by UsageCounts
DTC control strategy helps to obtain fast and smooth control in 3–phase induction motors. It does not depend upon the machine parameters and transformation of reference frames. Various control strategies on the Direct Torque Control (DTC) scheme have been carried out in the present study. The suggested scheme is meant for designing the low cost control circuit for DTC implementation on 3-phase SCIM. Three schemes with two types of inverters have been simulated in MATLAB (Simulink) environment and the THD ratio in each case has been studied along with Fast Fourier Transform (FFT) tools to compare the advantages.
2LI, 3LI, FOC, twelve sectors, FR-DTC, six sectors, ST-DTC
2LI, 3LI, FOC, twelve sectors, FR-DTC, six sectors, ST-DTC
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 8 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 2 | |
| downloads | 4 |

Views provided by UsageCounts