
pmid: 24500826
Study purpose Aseptic loosening of the acetabular component is the most common reason for revision after primary THA, and periprosthetic demineralisation has been described as a potential cause for this process. The trabeculae-oriented pattern (TOP)-cup is a flat, hydroxyapatite (HA)-coated titanium shell with a threaded rim that was developed in order to minimise periprosthetic bone loss. We hypothesised that this cup provides good primary stability and improves preservation of periprosthetic bone mineral density (BMD). Basic procedures A prospective cohort study on 30 patients receiving the TOP cup was carried out. Preoperative total hip BMD and postoperative periprosthetic BMD in five periprosthetic regions of interest were investigated by dual energy radiographic absorptiometry (DXA), cup migration was analysed by radiostereometry (RSA), and the Harris hips score (HHS) was determined. Main findings Mean HHS increased from 49 (24-79) preoperatively to 99 (92-100) after two years. DXA after one year demonstrated substantial BMD loss in the proximal periprosthetic zones 1 (-18%), zone 2 (-16 %) and zone 3 (-9%, all p≤0.001 when compared with baseline BMD determined immediately postoperatively). The bone loss in these regions did not recover after two years. RSA (performed on 16 patients) showed that only very limited micromotion of the implant occurred: Mean cranial migration was 0.01 mm (95% confidence interval (CI): −0.09-0.12) and mean inclination decreased by 0.02° (CI: −0.43-0.39) after two years. conclusion We conclude that the TOP cup provides good primary stability in the short-term. However, substantial BMD loss in proximal periprosthetic areas indicates that the design of this cup cannot prevent periprosthetic bone loss that has also been observed around other uncemented cups.
Adult, Male, Time Factors, Arthroplasty, Replacement, Hip, Biocompatible Materials, Middle Aged, Radiostereometric Analysis, Osteoarthritis, Hip, Absorptiometry, Photon, Durapatite, Coated Materials, Biocompatible, Bone Density, Humans, Female, Prospective Studies, Aged
Adult, Male, Time Factors, Arthroplasty, Replacement, Hip, Biocompatible Materials, Middle Aged, Radiostereometric Analysis, Osteoarthritis, Hip, Absorptiometry, Photon, Durapatite, Coated Materials, Biocompatible, Bone Density, Humans, Female, Prospective Studies, Aged
| citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 13 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
