The viscosity of the dilute phase of a3He-4He solution has been measured using a vibrating wire viscometer situated in the mixing chamber of a dilution refrigerator. The viscosity was extracted from the damping of the resonator for temperatures between 3.7 mK and 100 mK. In the low-temperature Fermi liquid regime ηT2=48×10−9 N sec m−2 K2. For temperatures less than 100 mK, the viscometer is a useful secondary thermometer that is not strongly dependent on the applied magnetic field.
530
530
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 45 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |