
doi: 10.1002/cta.455
handle: 11499/7104
AbstractIn this paper, four different‐type second‐order current‐mode filters, employing second‐generation current‐controlled conveyors (CCCIIs) and two capacitors, are proposed. The first two of the presented filters can simultaneously realize high‐output impedance low‐pass, band‐pass and high‐pass responses. Also, the two filters can provide notch and all‐pass filter responses with interconnection of the relevant output currents. The first developed one needs no critical active and passive element matching conditions and/or cancellation constraints. The second and third introduced ones employ only grounded capacitors. The fourth proposed filter derived from the third one uses only plus‐type single output CCCIIs (CCCII+s). The fifth filter can be constructed using commercially available active devices such as AD844s along with additional resistors instead of CCCII+s of the fourth proposed filter to perform experimental test easily. All of the proposed filters have low active and passive element sensitivities. Time and frequency domain analyses are performed for the first, second and third realized filters using SPICE simulation program. Also, experimental test is achieved for the fifth filter. In this study, stability problems attributed to non‐ideal gains of the CCCIIs and signal limitations of the first, second and third introduced filters due to restricted power supply voltages are investigated. Copyright © 2007 John Wiley & Sons, Ltd.
Energy storage, Testing, Current-controlled conveyors, Capacitance, All pass (AP) filters, Experimental testing, Capacitors, Frequency-domain (FD), Low-pass, Output currents, Current-mode circuits, Paper capacitors, Electric currents, Wave filters, Second orders, High pass, Active filters, SPICE, Band pass, Grounded capacitors, Current mode filter (CMF), Passive elements, Generation current, Output impedance, Analog filters, Single output, Electric filters, Passive filters, Computer simulation, Ketones, SPICE simulations, Electric equipment, current-controlled conveyors; current-mode circuits; analog filters;, 620, signal limitations; stability problems, Matching conditions, Power supply voltages, Dielectric devices, Low pass filters, Notch filters, Stability problems, Signal limitations, Sensitivity analysis, Active devices, High pass filters
Energy storage, Testing, Current-controlled conveyors, Capacitance, All pass (AP) filters, Experimental testing, Capacitors, Frequency-domain (FD), Low-pass, Output currents, Current-mode circuits, Paper capacitors, Electric currents, Wave filters, Second orders, High pass, Active filters, SPICE, Band pass, Grounded capacitors, Current mode filter (CMF), Passive elements, Generation current, Output impedance, Analog filters, Single output, Electric filters, Passive filters, Computer simulation, Ketones, SPICE simulations, Electric equipment, current-controlled conveyors; current-mode circuits; analog filters;, 620, signal limitations; stability problems, Matching conditions, Power supply voltages, Dielectric devices, Low pass filters, Notch filters, Stability problems, Signal limitations, Sensitivity analysis, Active devices, High pass filters
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 36 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
