Downloads provided by UsageCounts
{"references": ["1.\tKapur, A. K., & Malik, A. K. (1991, August). Gas insulated substations in India-an overview. In TENCON'91. Region 10 International Conference on EC3-Energy, Computer, Communication and Control Systems (Vol. 1, pp. 461-466). IEEE.", "2.\tKoch, H. J. (Ed.). (2014). Gas insulated substations. John Wiley & Sons.", "3.\tInsulation Co-ordination - Part 1: Definitions, principles and rules IS/IEC 60071-1: 2006.", "4.\tCIGRE, W. (1990). 33.02, Guidelines for representation of network elements when calculating transients. CIGRE Technical Brochure, 39", "5.\tPovh, D., Schmitt, H., Valcker, O., & Wutzmann, R. (1996). Modelling and analysis guidelines for very fast transients. IEEE Transactions on Power Delivery, 11(4), 2028-2035.", "6.\tLu, T., & Zhang, B. (2005, August). Calculation of very fast transient overvoltages in GIS. In 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific (pp. 1-5). IEEE.", "7.\tLiu, S., Sheng, C., Meng, F., Wang, S., Wang, R., Zhang, Y., ... & He, W. (2016, September). Electric field disturbance caused by an unmanned aerial vehicle flying near the HV power transmission line. In 2016 IEEE International Conference on High Voltage Engineering and Application (ICHVE) (pp. 1-4). IEEE.", "8.\tKumar, A., & Mishra, M. K. (2008, December). VFT study for EHV-GIS substation. In National Power Systems Conference (NPSC).", "9.\tPinches, D. S., & Al-Tai, M. A. (2008, September). Very fast transient overvoltages generated by gas insulated substations. In 2008 43rd International Universities Power Engineering Conference (pp. 1-5). IEEE.", "10.\tRao, J. R., Amarnath, J., & Kamakshaiah, S. (2010, October). Accurate modelling of very fast transient overvoltages in a 245kV GIS and research on protection measures. In 2010 Annual Report Conference on Electrical Insulation and Dielectic Phenomena (pp. 1-4). IEEE."]}
Gas-insulated Substations play an important role in power systems today but are adversely affected by the generation of Very Fast Transient Overvoltages (VFTO). This paper presents an analysis of VFTOs generated in a 245kV GIS caused by the operation of the circuit breaker and disconnector. The entire substation is modelled in PSCAD-EMTDC using equivalent circuits to simulate the operation of the disconnector and circuit breaker. The VFTO is observed for its peak voltage, rise time and voltage gradient. The results from the simulation were discussed and it was found that the VFTO does not damage the system insulation.
Disconnector, GIS, PSCAD, VFTO
Disconnector, GIS, PSCAD, VFTO
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 11 | |
| downloads | 17 |

Views provided by UsageCounts
Downloads provided by UsageCounts