Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Article . 2018
License: CC BY
Data sources: Datacite
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Article . 2018
License: CC BY
Data sources: Datacite
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Article . 2018
License: CC BY
Data sources: ZENODO
versions View all 2 versions
addClaim

Innovative Fabric Integrated Thermal Storage Systems And Applications

Authors: Ahmed Elsayed; Andrew Shea; Nicolas Kelly; John Allison;

Innovative Fabric Integrated Thermal Storage Systems And Applications

Abstract

{"references": ["I. Savvidou. \"Concept House Fa\u00e7ade. Integration of ceramics and loam in prefabricated facade panels\" Thesis report, 2010, Netherlands.", "P. Belzile, S. Kajl, D. Rousse, L. Lamarche, Y. Dutil. \"Thermal Storage Below house Basement\" Innostock 2012, 12th International conference on Energy storage.", "M. Gokul, A Krishnan. \"Comparative studies on heat transfer and fluid flow in cored brick and pebble bed heaters\" International Journal of Research in Engineering and Technology, 4 (01), 2015.", "S. Unalan, E. Ozrahat. \"The concrete columns as a sensible thermal energy storage medium and a heater\" Heat Mass Transfer, 2014, 50:10371052.", "E Ozrahat. S. Unalan. \"Thermal performance of a concrete column as a sensible thermal energy storage medium and a heater\" Renewable Energy 111 (2017) 561-579.", "L Parasad, P. Muthukumar. \"Design and optimization of lab-scale sensible heat storage prototype for solar thermal power plant application\" Solar Energy 2013, 97, 217-229.", "F. Bai, C. Xu. \"Performance analysis of a two-stage thermal energy storage system using concrete and steam accumulator\" Applied Thermal Engineering 31, 2011, 2764-2771.", "Ansys Fluent Release 17, ANSYS Inc., 27 Jan 2016.", "D. Caccavelli, B. Bedouani, J. Baude. \"Modelling and dimensioning a hot water floor heating system\" in: Proceedings of the 4th International Building Performance Simulation (IBPSA) Conference 1995, Madison, Wisconsin, United States. \n[10]\tMahmood Ranai, Nahid Nemati. \"Numerical Study of the Effects of Water-Al2O3 Nanofluid on Under Floor Heating System\" J. Energy Power Sources. Vol. 2, No. 1, 2015, pp. 22-31.\n[11]\tC Rao, H Niyas, P. Muthukumar. \"Performance tests on lab-scale sensible heat storage prototype. Applied Thermal Engineering\" https://doi.org/10.1016/j.applthermaleng.2017.10.085.\n[12]\tCIBSE Guide A. Environmental design. 3-38, CIBSE, 2015, London.\n[13]\tA Elsayed, R Al-dadah, S Mahmoud, A Rezk. \"Numerical investigation of turbulent flow heat transfer and pressure drop of AL2O3/water nanofluid in helically coiled tubes\" International Journal of Low-Carbon Technologies 10(3), January 2014. \n[14]\tDynalene Propylene Glycol Series. http://www.dynalene.com/v/vspfiles/templates/210/datasheets/Dynalene_PG_Technical_Data_Sheet.pdf.\n[15]\tL. Eppelbaum, I Kutasov, A. Pilchin. \"Thermal Properties of Rocks and density of Fluids. Applied Geothermics\" Edition: Lecture Notes in Earth System Sciences, Publisher: Springer, pp.99-149.\n[16]\tB. Xu, J. xiao, A. Kumar, P. Li, Y. Yang. \"Thermal storage using sand saturated by thermal-conductive fluid and comparison with the use of concrete\" Journal of Energy Storage 13, 2017, 85-95."]}

In northern European climates, domestic space heating and hot water represents a significant proportion of total primary total primary energy use and meeting these demands from a national electricity grid network supplied by renewable energy sources provides an opportunity for a significant reduction in EU CO2 emissions. However, in order to adapt to the intermittent nature of renewable energy generation and to avoid co-incident peak electricity usage from consumers that may exceed current capacity, the demand for heat must be decoupled from its generation. Storage of heat within the fabric of dwellings for use some hours, or days, later provides a route to complete decoupling of demand from supply and facilitates the greatly increased use of renewable energy generation into a local or national electricity network. The integration of thermal energy storage into the building fabric for retrieval at a later time requires much evaluation of the many competing thermal, physical, and practical considerations such as the profile and magnitude of heat demand, the duration of storage, charging and discharging rate, storage media, space allocation, etc. In this paper, the authors report investigations of thermal storage in building fabric using concrete material and present an evaluation of several factors that impact upon performance including heating pipe layout, heating fluid flow velocity, storage geometry, thermo-physical material properties, and also present an investigation of alternative storage materials and alternative heat transfer fluids. Reducing the heating pipe spacing from 200 mm to 100 mm enhances the stored energy by 25% and high-performance Vacuum Insulation results in heat loss flux of less than 3 W/m2, compared to 22 W/m2 for the more conventional EPS insulation. Dense concrete achieved the greatest storage capacity, relative to medium and light-weight alternatives, although a material thickness of 100 mm required more than 5 hours to charge fully. Layers of 25 mm and 50 mm thickness can be charged in 2 hours, or less, facilitating a fast response that could, aggregated across multiple dwellings, provide significant and valuable reduction in demand from grid-generated electricity in expected periods of high demand and potentially eliminate the need for additional new generating capacity from conventional sources such as gas, coal, or nuclear.

Related Organizations
Keywords

load shifting, demand side management, energy storage, FITS, renewable energy integration., Fabric integrated thermal storage

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 31
    download downloads 19
  • 31
    views
    19
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
0
Average
Average
Average
31
19
Green