Downloads provided by UsageCounts
{"references": ["P. Kundur, Power system Stability and Control. The ERPI Power system\nEngineering Series, 1994, pp. 17.", "V. Jalili-Marandi, \"Instantaneous relaxation-based real-time transient\nStability Simulation,\" IEEE Trans. Power Systems, vol. 24, no. 3,\npp.1327-1336, Aug. 2009 .", "Chen Shen, Jian Wang, \"Distributed transient stability simulation of\npower systems based on a jacobian-free newton-GMRES method,\" IEEE\nTrans. Power Systems, vol. 24, no. 1, pp.146-156, Feb. 2009.", "Y. Sasaki, E. Popov, N. Yorino, and Y. Zoka, \"A real-time robust\ndynamic ELD against uncertainties of renewable energy sources,\"\nInnovative Smart Grid Technologies Europe, No. ISGT351, pp.1-5, Oct.\n2013.", "Yan Xu, Zhao Yang Dong, Ke Meng, Jun Hua Zhao, Kit Po Wong, \"A\nhybrid method for transient stability-constrained optimal power flow\ncomputation,\" IEEE Trans. Power Systems, vol. 27, no. 4, pp. 1769-1777,\nNov. 2012.", "L. Hakim, J. Kubokawa, N. Yorino, Y. Zoka, Y. Sasaki, \"Total transfer\ncapability assessment incorporating corrective controls for transient\nstability using TSCOPF,\" IEEJ Trans. on Power and Energy, Vol. 130,\nNo.4, pp.399-406, April 2010.", "Minghui Yin, C. Y. Chung, K. P. Wong, Yusheng Xue, Yun Zou, \"An\nimproved iterative method for assessment of multi-swing transient\nstability limit,\" IEEE Trans. Power Systems, vol. 26, no. 4, pp.2023-2030,\nNov. 2011.", "T. Odun-Ayo, M. L. Crow, \"Structure-preserved power system transient\nstability using stochastic energy functions,\" IEEE Trans. Power Systems,\nvol. 27, no. 3, pp.1450-1458, Aug. 2012.", "H. D. Chiang and J. S. Thorp, \"The closest unstable equilibrium point\nmethod for power system dynamic security assessment,\" IEEE Trans.\nCircuits Syst, vol. 36, pp. 1187\u20131199, Dec. 1989.\n[10] C. W. Liu, J.S Thorp, \"A novel method to compute the closest unstable\nequilibrium point for transient stability region estimate in power\nsystems,\" IEEE Trans on Circuits and Systems I: Fundamental Theory\nand Applications, Vol. 44, No. 7, pp. 630 -635, July 1997.\n[11] G. D. Irisarri, G. C. Ejebe and J. G. Waight, \"Efficient solution for\nequilibrium points in transient energy function analysis,\" IEEE Trans. on\nPower Systems, vol. 9, no. 2, pp. 693-699, 1994.\n[12] H. D. Chiang, F. Wu, and P. Varaiya, \"A BCU method for direct analysis\nof power system transient stability,\" IEEE Trans. Power Systems, vol. 9,\nno. 3, 1994.\n[13] H. D. Chiang, C. C. Chu, and G. Cauley, \"Direct stability analysis of\nelectric power systems using energy functions: Theory, applications, and\nperspective,\" Proceedings of the IEEE, vol. 83, no. 11, 1995.\n[14] Y. Mansour, E. Vaahedi, A. Y. Chang, B. R. Corns, B. W. Garrett, K.\nDemaree, T. Athey, and K. Cheung, \"B. C. Hydro's On-line transient\nstability assessment (TSA): Model development, analysis, and\npost-processing,\" IEEE Trans. Power Systems, vol. 10, no. 1, pp.\n241-253, 1995.\n[15] L. F. C. Alberto, and N. G. Bretas, \"Application of Melnikov's method\nfor computing heteroclinic orbits in a classical SMIB power system\nmodel,\" IEEE Trans. CAS-I, 47-7, pp. 1085-1089, 2000.\n[16] A. C. Xue, F. F. Wu, Y. X. Ni, Q. Lu and S. W. Mei, \"Power system\ntransient stability assessment based on quadratic approximation of\nstability region,\" Electric Power Systems Research. Vol.76, No. 9/10,\npp.709-715, 2006.\n[17] J. T. Scruggs, L. Mili, \"Dynamic gradient method for PEBS detection in\npower system transient stability assessment,\" Int Jour of Electrical Power\nand Energy Systems, Vol. 23, No.2, pp. 155-165, 2001.\n[18] N. Kakimoto, Y. Ohsawa and M. Hayashi, \"Transient stability analysis of\nelectric power system via lur6 type Liapunov function.\" Trans. IEE of\nJapan, vol. 98, No. 5/6, May/June 1978.\n[19] A. Llamas, J. De La Ree Lopez, L. Mili, A. G. Phadke, and J. S. Thorp,\n\"Clarifications of the BCU method for transient stability analysis,\" IEEE\nTrans. Power Systems, vol. 10, no. 1, pp. 210-219, 1995.\n[20] F. Paganini, and B. C. Lesieutre, \"Generic properties, one-parameter\ndeformations, and the BCU Method,\" IEEE Trans. CAS-I, 46-6,\npp.760-763, 1999.\n[21] I. S Nazareno, L. F. C. Alberto and N. G. Bretas, \"Problems in the precise\ndetermination of BCU's controlling unstable equilibrium points and\nPEBS's exit point method in real-time transient stability analysis,\"\nTransmission and Distribution Conference and Exposition: Latin\nAmerica, pp. 475-480, Nov. 2004.\n[22] R. T. Treinen, V. Vittal, and W. Kliemann, \"An improved technique to\ndetermine the controlling unstable equilibrium point in a power system,\"\nIEEE Trans. Circuit and Systems, vol. 43, no. 4, pp. 313-323, 1996.\n[23] Y. Kataoka, Y. Tada, H. Okamoto, and R. Tanabe, \"Improvement of\nsearch efficiency of unstable equilibrium for transient stability\nassessment,\" in National Convention Record, IEE of Japan Power\nSystem, pp. 1349-1350, 1999. (in Japanese)\n[24] I. Luna-Lopez, J. M. Canedo, A. Loukianov, \"Dynamical method for\nCUEP detection in power system transient stability assessment,\" In Proc.\nof IEEE Power Engineering Society Winter Meeting, 2002. Vol. 1, pp.\n189-194, 2002.\n[25] Z. D. Li, S. Liu and C. Chen, \"New algorithm for the solution of\ncontrolling unstable equilibrium point,\" International Conference on\nPower System Technology, Vol. 4, pp. 1999-2003, Kunming, Oct. 2002.\n[26] Lei Chen, Yong Min, Fei Xu, Kai-Peng Wang, \"A continuation-based\nmethod to compute the relevant unstable equilibrium points for power\nsystem transient stability analysis,\" IEEE Trans. Power Systems, vol. 24,\nno. 1, pp. 165 \u2013 172, 2009.\n[27] Ancheng Xue, Shengwei Mei, Bangpeng Xie, \"A comprehensive method\nto compute the controlling unstable equilibrium point,\" IEEE Electric\nUtility Deregulation and Restructuring and Power Technologies, Third\nInternational Conference, pp. 1115 \u2013 1120, 2008.\n[28] H.D. Chiang, Direct Methods for Stability Analysis of Electric Power\nSystems: Theoretical Foundation, BCU Methodologies, and Applications.\nWiley, 1 edition, 2010, pp. 80.\n[29] T. Athey, R. Podmore, and S. Virmani, \"A practical method for direct\nanalysis of transient stability,\" IEEE Trans. Power Apparatus and\nSys-tems, vol. PAS-98, pp. 573-584, 1979.\n[30] N. Yorino, A. Priyadi, H. Kakui, M. Takeshita, \" A new method for\nobtaining critical clearing time for transient stability,\" IEEE Trans.\nPower Systems, vol. 25, no. 3, pp. 1620 \u2013 1626, 2010.\n[31] N. Yorino, A. Priyadi, R.A. Mutalib, Y. Sasaki, Y. Zoka, H. Sugihara, \"A\ndirect method for obtaining critical clearing time for transient stability\nusing critical generator conditions,\" European Transactions on Electrical\nPower, vol. 22, issue 5 pp.674 \u2013 687. 2010.\n[32] N. Yorino, E. Popov, Y. Zoka, Y. Sasaki, and H. Sugihara, \"An\napplication of critical trajectory method to BCU problem for transient\nstability studies,\" IEEE Transactions on Power Systems, Vol. 28, No. 4,\npp.4237-4244 , 2013.\n[33] E. Popov, N. Yorino, Y. Zoka, Y. Sasaki, and H. Sugihara, \"Robust\nmethod for detection of CUEP for power system transient stability\nscreening,\" Innovative Smart Grid Technologies Europe, No. ISGT316,\npp.1-5,Oct. 2013.\n[34] E Popov , N. Yorino, Y. Sasaki, Y. Zoka, and H. Sugihara, \"Robust\nmethod for detection of CUEP in power systems,\" IEEJ Transactions on\nPower and Energy, Vol.134, No.2, pp.1-9, Feb. 2014.\n[35] P. M. Anderson and A. A. Fouad, Power System Control and Stability.\nWiley-IEEE Press, 2002, pp. 38."]}
This paper discusses the performance of critical trajectory method (CTrj) for power system transient stability analysis under various loading settings and heavy fault condition. The method obtains Controlling Unstable Equilibrium Point (CUEP) which is essential for estimation of power system stability margins. The CUEP is computed by applying the CTrjto the boundary controlling unstable equilibrium point (BCU) method. The Proposed method computes a trajectory on the stability boundary that starts from the exit point and reaches CUEP under certain assumptions. The robustness and effectiveness of the method are demonstrated via six power system models and five loading conditions. As benchmark is used conventional simulation method whereas the performance is compared with and BCU Shadowing method.
Energy function method., Transient stability, Critical trajectory method, Power system
Energy function method., Transient stability, Critical trajectory method, Power system
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 6 | |
| downloads | 6 |

Views provided by UsageCounts
Downloads provided by UsageCounts