Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ ZENODOarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
ZENODO
Other literature type . 2008
License: CC BY
Data sources: ZENODO
https://dx.doi.org/10.4122/1.1...
Other literature type . 2008
Data sources: Datacite
versions View all 2 versions
addClaim

Analysis method for determining sufficient water vapour retarder in timber-framed walls

Authors: Vinha, Juha; Vinha, Juha;

Analysis method for determining sufficient water vapour retarder in timber-framed walls

Abstract

The moisture performance of timber-framed external wall assemblies with and without a vapour barrier has been the subject of continuous discussion in Finland as well as other countries for several decades. It still remains one of the most hotly contested issues in building physics research. Despite numerous studies, agreement has not been reached on the minimum water vapour resistance that should be required of the interior wall lining of a wall assembly under different conditions. Consequently, different guidelines and regulations for water vapour resistance values of vapor retarders exist also in countries located in highly similar climatic conditions. This paper presents the new analysis method for determining sufficient water vapour retarder in timber-framed walls. It contains ten years research results examined by laboratory tests, field tests and calculation analyses in Tampere University of Technology, Finland. The basis of this method is that all factors affect to the water vapor diffusion in wall assemblies have been taken into account. Comprehensive assessment of the moisture performance of wall assemblies requires establishing the performance criteria and limit values that an assembly must meet, the outdoor and indoor conditions to be used in designing moisture performance, and the assembly solution and used materials as well as their building physical properties. The acceptability of the moisture performance of an external wall assembly depends essentially on all these factors during the service life of a building. The research results indicate that a plastic vapour barrier behind the interior board is safe in all typical indoor and outdoor air conditions occurring in Finnish climatic conditions. However, a wall may be implemented also without a plastic vapour barrier in the interior wall lining. Then, the required water vapour resistance ratio between the interior and exterior wall linings depends on the sheathing and thermal insulation used. In winter conditions, the minimum water vapour resistance values between the interior and exterior wall linings are typically in the 0 to 80:1 range. The key properties of the layers which improve the moisture performance of a wall assembly are the high thermal resistance and low water vapour resistance of the sheathing.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 2
    download downloads 2
  • 2
    views
    2
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
0
Average
Average
Average
2
2
Green