Downloads provided by UsageCounts
Power-quality events and operation transients in power systems (PS) with isolated neutral can saturate inductive voltage transformers (IVT), which, when interacting with the overhead and underground cable capacitances, can cause ferroresonance events in the local PS. This abnormal operating mode can partially or totally damage the transformers and switchgears within the affected PS. Distribution system operators (DSO) can minimize these effects by detecting ferroresonance events accurately and fast enough and changing the mode of operation accordingly. Direct detection methods, i.e., based on voltage measurements, are reliable, but the massive deployment of this solution is relatively expensive; i.e., power quality analyzers cost thousands of USD. Alternatively, indirect detection methods are also available, e.g., IVT vibration measurements with accelerometers costing hundreds of USD, but their reliability depends on the installation method used. This manuscript proposes using the acoustic noise caused by magnetostriction forces within the IVT core during ferroresonance events to detect their occurrence. Compared to other indirect methods, electret condenser microphones with preamplifying stage cost less than USD 10 and are less sensitive to the installation procedure. The proposed method is validated experimentally, and its performance compared to IVT vibration measurements one by using the same detection methodology.
Electric engineering, Ingeniería eléctrica, potential transformer, Chemical technology, Potential transformer, ferroresonance detection; inductive voltage transformer; potential transformer, TP1-1185, ferroresonance detection, Article, Inductive voltage transformer, inductive voltage transformer, Electrical engineering, Electrotecnia, Ferroresonance detection
Electric engineering, Ingeniería eléctrica, potential transformer, Chemical technology, Potential transformer, ferroresonance detection; inductive voltage transformer; potential transformer, TP1-1185, ferroresonance detection, Article, Inductive voltage transformer, inductive voltage transformer, Electrical engineering, Electrotecnia, Ferroresonance detection
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 6 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 279 | |
| downloads | 91 |

Views provided by UsageCounts