The rapid increase of data centre industry has stimulated the interest of both researchers and professionals in order to reduce energy consumption and carbon footprint of these unique infrastructures. The implementation of energy efficiency strategies and the use of renewables play an important role to reduce the overall data centre energy demand. Information Technology (IT) equipment produce vast amount of heat which must be removed and therefore waste heat recovery is a likely energy efficiency strategy to be studied in detail. To evaluate the potential of heat reuse a unique liquid cooled data centre test bench was designed and built. An extensive thermal characterization under different scenarios was performed. The effective liquid cooling capacity is affected by the inlet water temperature. The lower the inlet water temperature the higher the liquid cooling capacity; however, the outlet water temperature will be also low. Therefore, the requirements of the heat reuse application play an important role in the optimization of the cooling configuration. The experimental data was then used to validate a dynamic energy model developed in TRNSYS. This model is able to predict the behaviour of liquid cooling data centres and can be used to study the potential compatibility between large data centres with different heat reuse applications. The model also incorporates normalized power consumption profiles for heterogeneous workloads that have been derived from realistic IT loads.
Peer Reviewed
Àrees temàtiques de la UPC::Informàtica::Aplicacions de la informàtica, Àrees temàtiques de la UPC::Energies::Eficiència energètica, Liquid cooling, Data centre; Liquid cooling; IT load; Experimentation; Numerical modelling, Data centre, Numerical modelling, IT load, Energia -- Consum -- Models matemàtics, Energy consumption -- Mathematical models, Experimentation
Àrees temàtiques de la UPC::Informàtica::Aplicacions de la informàtica, Àrees temàtiques de la UPC::Energies::Eficiència energètica, Liquid cooling, Data centre; Liquid cooling; IT load; Experimentation; Numerical modelling, Data centre, Numerical modelling, IT load, Energia -- Consum -- Models matemàtics, Energy consumption -- Mathematical models, Experimentation
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 70 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 1% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 46 | |
| downloads | 210 |

Views provided by UsageCounts
Downloads provided by UsageCounts