Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Radiation Exposure to the Surgeon and the Patient During Posterior Lumbar Spinal Instrumentation

A Prospective Randomized Comparison of Navigated Versus Non-navigated Freehand Techniques
Authors: Jimmy, Villard; Yu-Mi, Ryang; Andreas K, Demetriades; Andreas, Reinke; Michael, Behr; Alexander, Preuss; Bernhard, Meyer; +1 Authors

Radiation Exposure to the Surgeon and the Patient During Posterior Lumbar Spinal Instrumentation

Abstract

A prospective randomized study.To compare occupational radiation exposure to the surgeon, as well as the patient, during posterior lumbar spine instrumentation in 10 navigated cases (navigated) versus 11 cases using the freehand technique (non-navigated).The use of navigation increases the accuracy of posterior lumbar instrumentation.A further speculated benefit of navigation is the reduction of radiation exposure of the surgeon. However, this has so far not been evaluated in such comparative manner.Radiation exposure to the surgeon was measured by digital dosimeters placed at the level of the eye, chest, and dominant forearm. Radiation exposure was measured from the time of positioning of the patient to the end of the procedure both for navigated (intraoperative 3-dimensional [3D] fluoroscopy-based) and non-navigated (2-dimensional fluoroscopy-guided) freehand posterior lumbar spine instrumentations. A 3D fluoroscopic scan was routinely performed at the end of the procedure for all patients.Patients were distributed evenly in the 2 groups in terms of sex, age, body mass index, and the number of operated levels. The accumulated radiation dose for the surgeon was significantly higher in the non-navigated group; up to 9.96 times. The radiation dose for the patient was higher with the freehand technique, 1884.8 cGy·cm (non-navigated) versus 887 cGy·cm (navigated), without reaching a statistically significant level.Radiation exposure to the surgeon during pedicle screw placement with the freehand technique is up to 9.96 times greater than with the use of navigation. In the latter group, the only radiation exposure comes from the preoperative-level control and positioning of the 3D C-arm before 3D fluoroscopic acquisition. Furthermore, neuronavigation also reduces the cumulative dose for the patient.2.

Keywords

Aged, 80 and over, Male, Surgeons, Inpatients, Film Dosimetry, Lumbar Vertebrae, Middle Aged, Radiation Dosage, Spinal Fusion, Surgery, Computer-Assisted, Pedicle Screws, Fluoroscopy, Occupational Exposure, Humans, Female, Prospective Studies, Neuronavigation, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    151
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 1%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 1%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
151
Top 1%
Top 1%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!