It has been postulated that differences in provocative concentration of methacholine causing a 20% fall in FEV1 (PC20) values between the dosimeter method and tidal breathing method might be due to differences in the dose of agonist delivered to the mouth. The aim of the present study was to determine the influence of the dose of aerosol delivered to the mouth on differences in the response obtained with each challenge method.This study measured airway responsiveness to methacholine by dosimeter method and tidal breathing method in 27 subjects with suspected asthma. The dosimeter was modified to deliver an identical volume to that obtained with the tidal breathing method. Concentration-response curves were characterized by the PC20.The dosimeter method PC20 was significantly higher than the tidal breathing method PC20, with geometric mean values of 4.03 (95% confidence interval [CI], 1.86 to 8.78 mg/mL) and 2.19 (95% CI, 1.32 to 3.64 mg/mL; p = 0.04), respectively. The mean difference in the PC20 value detected with each method was similar in subjects with tidal breathing method PC20 values > or = 2 mg/mL (0.77 doubling concentrations) and in those with PC20 values < 2 mg/mL (0.96 doubling concentrations; p = 0.83).The tidal breathing method produces PC20 values significantly lower than a modified dosimeter method, which delivers the same volume of aerosol. These results suggest that the discordant PC20 values obtained with the two methods are not due to differences in the dose of agonist delivered to the mouth.
Adult, Male, Cross-Over Studies, Dose-Response Relationship, Drug, Nebulizers and Vaporizers, Asthma, Bronchial Provocation Tests, Bronchoconstrictor Agents, Cohort Studies, Predictive Value of Tests, Forced Expiratory Volume, Administration, Inhalation, Tidal Volume, Humans, Female, Methacholine Chloride
Adult, Male, Cross-Over Studies, Dose-Response Relationship, Drug, Nebulizers and Vaporizers, Asthma, Bronchial Provocation Tests, Bronchoconstrictor Agents, Cohort Studies, Predictive Value of Tests, Forced Expiratory Volume, Administration, Inhalation, Tidal Volume, Humans, Female, Methacholine Chloride
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 8 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |