Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Edinburgh Research A...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 1 versions
addClaim

Hybrid HVDC transformer for multi-terminal networks

Authors: Smailes, Michael Edward;

Hybrid HVDC transformer for multi-terminal networks

Abstract

There is a trend for offshore wind farms to move further from the point of common coupling to access higher and more consistent wind speeds to reduce the levelised cost of energy. To accommodate these rising transmission distances, High Voltage Direct Current (HVDC) transmission has become increasingly popular. However, existing HVDC wind farm topologies and converter systems are ill suited to the demands of offshore operation. The HVDC and AC substations have been shown to contribute to more than 20% of the capital cost of the wind farm and provide a single point of failure. Therefore, many wind farms have experienced significant delays in construction and commissioning, or been brought off line until faults could be repaired. What is more, around 75% of the cost of the HVDC and AC substations can be attributed to structural and installation costs. Learning from earlier experiences, industry is now beginning to investigate the potential of a modular approach. In place of a single large converter, several converters are connected in series, reducing substation individual size and complexity. While such options somewhat reduce the capital costs, further reductions are possible through elimination of the offshore substations altogether. This thesis concerns the design and evaluation the Hybrid HVDC Transformer, a high power, high voltage, DC transformer. This forms part of the platform-less (i.e. without substations) offshore DC power collection and distribution concept first introduced by the Offshore Renewable Energy Catapult. By operating in the medium frequency range the proposed Hybrid HVDC Transformer can be located within each turbine’s nacelle or tower and remove the need for expensive offshore AC and DC substations. While solid state, non-isolating DC-DC transformers have been proposed in the literature, they are incapable of achieving the step up ratios required for the Hybrid HVDC transformer [1]– [3]. A magnetic transformer is therefore required, although medium frequency and non-sinusoidal operation does complicate the design somewhat. For example, inter-winding capacitances are more significant and core losses are increased due to the added harmonics injected by the primary and secondary converters [1], [2]. To mitigate the impact of these complications, an investigation into the optimal design was conducted, including all power converter topologies, core shapes and winding configurations. The modular multilevel converter in this case proved to be the most efficient and practical topology however, the number of voltage levels that could be generated on the primary converter was limited by the DC bus voltage. To avoid the use of pulse width modulation and hence large switching losses, a novel MMC control algorithm is proposed to reduce the magnitude of the converter generated harmonics while maintaining a high efficiency. The development and analysis of this High Definition Modular Multilevel Control algorithm forms the bulk of this thesis’ contribution. While the High Definition Modular Multilevel Control algorithm was developed initially for the Hybrid HVDC Transformer, analysis shows it has several other potential applications particularly in medium and low voltage ranges.

Country
United Kingdom
Related Organizations
Keywords

HD-MMC, power conversion, transformer, offshore wind, multilevel converter, DC transformer, MMC

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Green