Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Pure Utrecht Univers...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Pure Utrecht University
Conference object . 2001
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
DBLP
Conference object . 2024
Data sources: DBLP
DBLP
Article . 2020
Data sources: DBLP
versions View all 8 versions
addClaim

F-information measures in medical image registration.

Authors: Pluim, J.P.W.; Maintz, J.B.A.; Viergever, M.A.;

F-information measures in medical image registration.

Abstract

A measure for registration of medical images that currently draws much attention is mutual information. The measure originates from information theory, but has been shown to be successful for image registration as well. Information theory, however, offers many more measures that may be suitable for image registration. These all measure the divergence of the joint distribution of the images' grey values from the joint distribution that would have been found had the images been completely independent. This paper compares the performance of mutual information as a registration measure with that of other F-information measures. The measures are applied to rigid registration of positron emission tomography (PET)/magnetic resonance (MR) and MR/computed tomography (CT) images, for 35 and 41 image pairs, respectively. An accurate gold standard transformation is available for the images, based on implanted markers. The registration performance, robustness and accuracy of the measures are studied. Some of the measures are shown to perform poorly on all aspects. The majority of measures produces results similar to those of mutual information. An important finding, however, is that several measures, although slightly more difficult to optimize, can potentially yield significantly more accurate results than mutual information.

Country
Netherlands
Keywords

Diagnostic Imaging, Models, Statistical, Brain, Information Storage and Retrieval, Reproducibility of Results, Numerical Analysis, Computer-Assisted, Signal Processing, Computer-Assisted, Image Enhancement, Magnetic Resonance Imaging, Models, Biological, Sensitivity and Specificity, Pattern Recognition, Automated, Imaging, Three-Dimensional, Artificial Intelligence, Positron-Emission Tomography, Subtraction Technique, Image Interpretation, Computer-Assisted, Humans, Wiskunde en Informatica (WIIN), Computer Simulation, Algorithms

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    91
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
91
Top 10%
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!