image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Archivio istituziona...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
addClaim

Design of the shunt resistor for a DC Resistive SFCL

Authors: IMPARATO, SALVATORE; MORANDI, ANTONIO; FABBRI, MASSIMO; NEGRINI, FRANCESCO; RIBANI, PIER LUIGI;

Design of the shunt resistor for a DC Resistive SFCL

Abstract

A DC-operating resistive-type superconducting fault current limiter for AC applications (in short a “DC Resistive SFCL”) is based on the synergistic use of the resistive and the rectifier fault current limiter concepts, and allows the superconductor to operate in nearly DC current conditions. This regime of operation drastically reduces AC losses thus opening completely new perspectives with regard to materials, architecture of the cable, lay out of windings and cryogenics. In this paper, some configuration of the superconducting coil able to produce the required inductive and resistive effect in the central branch of the rectifier bridge are investigated. Appropriate connections of external shunt resistor in order to reduce the Joule heating during the limiting phase without the need of one additional current leader are considered. Numerical simulation with reference to application of the proposed SFCL to 20 kV distribution system are carried out by means EMTP software.

Country
Italy
Keywords

CRYOGEN FREE COOLING; FAULT CURRENT LIMITER; SMART-GRID

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!