Downloads provided by UsageCounts
arXiv: 1903.12531
handle: 10261/213640 , 11572/258049 , 11568/1027926 , 11582/323330
Test beam results obtained with 3D pixel sensors bump-bonded to the RD53A prototype readout ASIC are reported. Sensors from FBK (Italy) and IMB-CNM (Spain) have been tested before and after proton-irradiation to an equivalent fluence of about $1$ $\times$ $10^{16}$ $\text{n}_{\text{eq}}$ cm$^{-2}$ (1 MeV equivalent neutrons). This is the first time that one single collecting electrode fine pitch 3D sensors are irradiated up to such fluence bump-bonded to a fine pitch ASIC. The preliminary analysis of the collected data shows no degradation on the hit detection efficiencies of the tested sensors after high energy proton irradiation, demonstrating the excellent radiation tolerance of the 3D pixel sensors. Thus, they will be excellent candidates for the extreme radiation environment at the innermost layers of the HL-LHC experiments.
Conference Proceedings of VCI2019, 15th Vienna Conference of Instrumentation, February 18-22, 2019, Vienna, Austria. arXiv admin note: text overlap with arXiv:1903.01963
Radiation damage to detector materials (solid state), Performance of high energy physics detectors, Physics - Instrumentation and Detectors, 610, FOS: Physical sciences, Performance of high energy physics detectors; Pixelated detectors and; associated VLSI electronics; Radiation-hard electronics; Radiation; damage to detector materials (solid state); Radiation-hard detectors, Instrumentation and Detectors (physics.ins-det), 530, 7: Advanced hybrid pixel detectors, Pixelated detectors and associated VLSI electronics, Performance of high energy physics detectors; Pixelated detectors and associated VLSI electronics; Radiation damage to detector materials (solid state); Radiation-hard detectors; Radiation-hard electronics, Detectors and Experimental Techniques, physics.ins-det, Radiation-hard electronics, Radiation-hard detectors
Radiation damage to detector materials (solid state), Performance of high energy physics detectors, Physics - Instrumentation and Detectors, 610, FOS: Physical sciences, Performance of high energy physics detectors; Pixelated detectors and; associated VLSI electronics; Radiation-hard electronics; Radiation; damage to detector materials (solid state); Radiation-hard detectors, Instrumentation and Detectors (physics.ins-det), 530, 7: Advanced hybrid pixel detectors, Pixelated detectors and associated VLSI electronics, Performance of high energy physics detectors; Pixelated detectors and associated VLSI electronics; Radiation damage to detector materials (solid state); Radiation-hard detectors; Radiation-hard electronics, Detectors and Experimental Techniques, physics.ins-det, Radiation-hard electronics, Radiation-hard detectors
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 8 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 70 | |
| downloads | 122 |

Views provided by UsageCounts
Downloads provided by UsageCounts