Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Acta Physica Sinicaarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Acta Physica Sinica
Article . 2020 . Peer-reviewed
Data sources: Crossref
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Acta Physica Sinica
Article
License: CC BY
Data sources: UnpayWall
versions View all 1 versions
addClaim

Vacuum metrology based on refractive index of gas

Authors: Yu-Rong Xu; Yang-Yang Liu; Jin Wang; Yu Sun; Zhen-Hua Xi; De-Tian Li; Shui-Ming Hu;

Vacuum metrology based on refractive index of gas

Abstract

With the development of vacuum technology, subject to the influence of directional flow and uneven temperature, the thermodynamic equilibrium state is destroyed. In this case, the pressure reference is not suitable for characterizing the vacuum state. To ensure the long-term stability and reproducibility of the measurement system, vacuum metrology will be characterized by gas density. The precisive measurement of gas refractive index based on a Fabry-Perot cavity can be used to derive the gas density. This kind of an optical measurement of vacuum links macroscopic dielectric constants of gases with microscopic polarization parameters of atoms and molecules. It replaces the physical standard based on the mercury pressure gauge with the quantum standard. In this paper, we discuss the reverse process from refractive index to gas pressure, and use the laser-locked Fabry-Perot cavity method to measure the refractive index of argon gas. The contribution of related parameters to the uncertainty of determined gas pressure is analyzed. The influences of material parameters and experimental parameters such as gas molar susceptibility, molar susceptibility, dielectric second Virial coefficient and temperature on gas pressure accuracy are analyzed. The result shows that the uncertainty in our measurement of argon within 1 atm is <inline-formula><tex-math id="M2">\begin{document}$u = \sqrt {{{(6\;{\rm{mPa}})}^2} + {{(73 \times {{10}^{ - 6}}p)}^2}} $\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="15-20200706_M2.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="15-20200706_M2.png"/></alternatives></inline-formula>. Currently, the uncertainty mainly comes from the measurement deviation of gas temperature inside the cavity. After repeating the measurement a few times, the results show that the statistical uncertainty of refractive index is within 100 ppm, which is limited by the accuracy of the pressure gauge used here. In addition, we compare the dipole calculated by the <i>ab initio</i> method with that by the DOSD method. The results show that the dynamic polarizability obtained by the <i>ab initio</i> method is consistent with our experimental results. In conclusion, these experimental results show that the measurement of gas pressure based on the gas refractive index has high repeatability and accuracy. If the temperature control and corresponding measurement accuracy of the gas are further improved, this method can also be used to obtain high-precision microscopic parameters such as the polarizabilities of atoms and molecules. In the future work, we will focus on improving the temperature control and the design of the cavity to reduce cavity leakage and deflation. It is possible that the measurement accuracy of the gas pressure will be increased to 10 ppm level, which is the same level as the current standard pressure gauge and will become a new standard for pressure measurement in the future.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    3
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
3
Average
Average
Average
gold