CALIDAD DE AIRE INTERIOR Y EFICIENCIA ENERGÉTICA

Authors: BEATRIZ RODRÍGUEZ SORIA; JOSÉ MARÍA PÉREZ BELLA; JAVIER DOMÍNGUEZ HERNÁNDEZ; ENRIQUE CANO SUÑEN; JUAN JOSÉ DEL COZ DÍAZ;

CALIDAD DE AIRE INTERIOR Y EFICIENCIA ENERGÉTICA

Abstract

The Spanish Building Technical Code, named CTE standard rule, establishes the present safety and habitability requirements in the building projects. This standard has been implemented in several phases since the year 2006. The CTE has adopted recent international approaches to other building standard rules, such as the performance-based codes or objectives,improving the previous prescriptive-based standards.This performance-based behaviour has been reached in some chapters of the standard rule more effectively than in others. The practical application of the standard Basic Documents (BD) HS3 (Indoor air quality), HE1 (Energy demand limits) and HE2 (Ef? ciency of heating/air-conditioning systems), to a specific building project gives place to an incoherent building solution. Moreover, in some cases both standard documents are incompatible.This research paper develops a critical valuation of the three BD’s of the CTE standard rule, showing the interferences in the practical application of the BD-HS3 standard with the other two rules: BD-HE1 and BD-HE2. Authors analyze the problems identified in relationship with the energy efficiency, thermal comfort and indoor air quality. A complete revision and correction measures are proposed for future modifications in the standard BD rules in order to fulfill the basic requirements at the different project, construction and final use phases.The changes in the code that are necessary are suggested, so as the technical systems that are able to satisfy in a performance way the demands resulting from the integral applications of the Basic Documents.

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!