
<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://www.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=undefined&type=result"></script>');
-->
</script>pmid: 22086572
Disturbances of the cardiac conduction system are potential complications after cardiac valve surgery.This study was designed to investigate the association between perioperative factors and atrio-ventricular block, the need for temporary cardiac artificial pacing and, if necessary, permanent pacemaker implantation after cardiac valve surgery.Retrospective analysis of the Cardiac Surgery Database - Hospital São Lucas/PUCRS. The data are collected prospectively and analyzed retrospectively.Between January 1996 and December 2008 were included 1102 valve surgical procedures: 718 aortic valves (65.2%), 407 (36.9%) mitral valve and 190 (17.2%) coronar artery bypass grafting combined with valve repair and 23 (2.1%) aortic and mitral combined surgery. 187 patients (17%) showed clinical and electrocardiographic pattern of atrio-ventricular block requiring artificial temporary pacing. Of these, 14 patients (7.5%) required permanent pacemaker implantation (1.27% of the total valve surgery patients). Multivariate analysis showed association of the incidence of atrio-ventricular block and temporary pacing with mitral valve surgery (OR 1,76; CI 95% 1.08-2.37; P = 0.002), implantation of bioprosthetic devices (OR 1.59; CI 95% 1.02-3.91; P = 0,039), age over 60 years (OR 1.99; CI 95% 1.352.85; P < 0.001), prior use of anti-arrhythmic drugs (OR 1.86; CI 95% 1.04-3.14; P = 0.026) and previous use of b-blocker (OR 1.76; CI 95% 1.25-2.54; P = 0.002). Remarkably the presence of atrio-ventricular block did not significantly show association with increased mortality, but significantly prolonged (P < 0.0001) hospital length-of-stay and, therefore, hospital costs.Our study presents a group of predictive factors referring to a specific patient profile by which high risk of atrio-ventricular block and the need of temporary cardiac pacing after cardiac valve surgery it is determined.
Heart Valve Prosthesis Implantation, Male, Cardiac Pacing, Artificial, Length of Stay, Middle Aged, Perioperative Care, Aortic Valve, Humans, Mitral Valve, Female, Coronary Artery Bypass, Atrioventricular Block, Epidemiologic Methods, Aged
Heart Valve Prosthesis Implantation, Male, Cardiac Pacing, Artificial, Length of Stay, Middle Aged, Perioperative Care, Aortic Valve, Humans, Mitral Valve, Female, Coronary Artery Bypass, Atrioventricular Block, Epidemiologic Methods, Aged
| citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 22 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
