Proposed and tested stand-alone renewable energy sources without the use of the energy output of the network. This is an important low-power renewable energy sources because there is no need to convert energy in the network when the be performed relatively expensive equipment. Sources are allocated to the commutated electric energy consumers, relatively inexpensive triac's switches. PLC control are provided the measurement of direct and indirect energy parameters. Verified that the switching process is the duration of the a user, even is not observed. Ill. 4, bibl. 3, tabl. 1 (in English; abstracts in English and Lithuanian).http://dx.doi.org/10.5755/j01.eee.114.8.703
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |