This in vitro study aimed to assess the presence of microgaps at the implant–abutment interface in monolithic zirconia partial implant-supported fixed prostheses on transepithelial abutments versus Ti-base abutments. Methods: Sixty conical connection dental implants were divided into two groups (n = 30). The control group consisted of three-unit bridge monolithic zirconia connected to two implants by a transepithelial abutment. The test group consisted of monolithic zirconia three-unit restoration connected to two implants directly by a titanium base (Ti-base) abutment. The sample was subjected to thermocycling (10,000 cycles at 5 °C to 55 °C, dwelling time 50 s) and chewing simulation (300,000 cycles, under 200 N at frequencies of 2 Hz, at a 30° angle). The microgap was evaluated at six points (mesiobuccal, buccal, distobuccal, mesiolingual, lingual, and distolingual) of each implant–abutment interface by using a scanning electron microscope (SEM). The data were analyzed using the Mann–Whitney U tests (p > 0.05). Results: The SEM analysis showed a smaller microgap at the implant–abutment interface in the control group (0.270 μm) than in the test group (3.902 μm). Statistically significant differences were observed between both groups (p < 0.05). Conclusions: The use or not of transepithelial abutments affects the microgap size. The transepithelial abutments group presented lower microgap values at the interface with the implant than the Ti-base group in monolithic zirconia partial implant-supported fixed prostheses. However, both groups had microgap values within the clinically acceptable range.
Implantes dentales, Dental prosthesis, odontologia, Dental implants, Dental implant–abutment design, 3314 Tecnología Médica, Article, 616.314-089.843, Dental abutments, 3299 Otras Especialidades Médicas, Aparatos y material odontológicos, Scanning electron microscopy, 616.314-089.28, Implant-supported
Implantes dentales, Dental prosthesis, odontologia, Dental implants, Dental implant–abutment design, 3314 Tecnología Médica, Article, 616.314-089.843, Dental abutments, 3299 Otras Especialidades Médicas, Aparatos y material odontológicos, Scanning electron microscopy, 616.314-089.28, Implant-supported
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 4 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |