The dynamic performance of the local control of single-phase voltage source inverters (VSIs) can be degraded when supplying to nonlinear loads (NLLs) in microgrids. When this control is based on the droop principles, a proper calculation of the active and reactive averaged powers (P–Q) is essential for a proficient dynamic response against abrupt NLL changes. In this work, a VSI supplying to an NLL was studied, focusing the attention on the P–Q calculation stage. This stage first generated the direct and in-quadrature signals from the measured load current through a second-order generalized integrator (SOGI). Then, the instantaneous power quantities were obtained by multiplying each filtered current by the output voltage, and filtered later by utilizing a SOGI to acquire the averaged P–Q parameters. The proposed algorithm was compared with previous proposals, while keeping the active power steady-state ripple constant, which resulted in a faster calculation of the averaged active power. In this case, the steady-state averaged reactive power presented less ripple than the best proposal to which it was compared. When reducing the velocity of the proposed algorithm for the active power, it also showed a reduction in its steady-state ripple. Simulations, hardware-in-the-loop, and experimental tests were carried out to verify the effectiveness of the proposal.
Total demand distortion, droop control, Electric networks, Droop control, single-phase, Active power, Xarxes elèctriques, Reactive power, nonlinear load, transient, inverter, Single-phase, Inverter, reactive power, Nonlinear load, Transient, Àrees temàtiques de la UPC::Enginyeria elèctrica, stability, total demand distortion, Settling- time, active power, Settling-time, Single‐phase, Àrees temàtiques de la UPC::Enginyeria electrònica, settling-time, Stability
Total demand distortion, droop control, Electric networks, Droop control, single-phase, Active power, Xarxes elèctriques, Reactive power, nonlinear load, transient, inverter, Single-phase, Inverter, reactive power, Nonlinear load, Transient, Àrees temàtiques de la UPC::Enginyeria elèctrica, stability, total demand distortion, Settling- time, active power, Settling-time, Single‐phase, Àrees temàtiques de la UPC::Enginyeria electrònica, settling-time, Stability
| citations The total number of citations received by all articles of the researcher of interest. | 10 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 181 | |
| downloads | 746 |

Views provided by UsageCounts
Downloads provided by UsageCounts