Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ https://download.atl...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
https://download.atlantis-pres...
Article
License: CC BY NC
Data sources: UnpayWall
https://doi.org/10.2991/icitmi...
Article . 2015 . Peer-reviewed
Data sources: Crossref
versions View all 1 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Reason Analysis for the increase of single-phase short circuit current and its suppressing measure

Authors: G. Chen; H. Zhang; Y. Li;

Reason Analysis for the increase of single-phase short circuit current and its suppressing measure

Abstract

KEYWORD: Single-phase short circuit current; Neutral grounding; Small reactance; Autotransformer ABSTRACT: Aiming at the issue that the single-phase short circuit current at the 220 kV bus of Chengdu 500kV substation exceeds the three-phase short current or even exceeds the breaking capacity of breaker, the reason is analyzed and the measure that main transformer neutral grounding by small reactance is put forward to reduce the single-phase short circuit. According to the planning power network of Sichuan, this paper analyzes the limiting effects of 500 kV autotransformer neutral grounding by small reactance on 220 kV single-phase short circuit current by simulation and calculation. This paper also analyzes the influence of neutral grounding by small reactance on insulation level of neutral point, and put forward a directive idea about small reactor's selection.

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    1
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
1
Average
Average
Average
gold