Stability of Precast Concrete Tilt Panels in Fire

Authors: Lim, Linus C S;

Stability of Precast Concrete Tilt Panels in Fire

Abstract

This report investigates the behaviour of slender cantilever concrete panels and concrete panels in steel frames exposed to elevated temperatures. This report also provides recommendations for the design of slender tilt-up wall panels for fire resistance. The current trend of tilt-up construction in industrial buildings utilises very tall and thin concrete wall panels that are reinforced with a single layer of reinforcing in the middle. These wall panels are cantilevered from the base and are not connected to a column or a portal frame. The panels are connected directly to the steel frame by a steel rafter or indirectly to the eaves tie. The analysis of this project was conducted using SAFIR, a non-linear finite element programme developed in the University of Liege, Belgium. Reinforced concrete walls subjected to a fire on one side will undergo non-uniform thermal expansion, causing the walls to bow. Free-standing concrete cantilever walls with slenderness ratios (Height to thickness ratio) in excess of 50 experience very large deflections when exposed to a fire on one side. The analyses have shown that these large deflections will lead to outward collapse of the walls onto the neighbouring property. Concrete cantilever walls connected to unbraced steel frames are dangerous as they cause the frame to sway and fall out onto the neighbouring property during a fire. Braced steel frames connected to the walls enhance the behaviour of the walls by preventing the large outward deflections of the panels. If bracing is available from the steel roof to prevent sway, the wall panels can be constructed up to 12 metres and slenderness ratios up to 96, without outward collapse or buckling failure of the wall panels. For the partially braced frames conducted in this study, the height of the wall panels should not exceed 9.0 metres and the slenderness ratios should not exceed 65. It is concluded that the deflections of the free standing cantilever walls should be controlled. Slender cantilever walls should be connected to a braced steel frame with well designed connections to the rafter and the eaves tie.

Country
New Zealand
Related Organizations
Keywords

690

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Related to Research communities
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!