Operation requirements of oscillating heat pipes (OHPs) are proposed. Based on the requirements, OHPs with nonflammable fluorocarbon fluids, FC-72 and FC-75, as the working fluid are developed. The OHPs have an inner diameter of 1.75 mm, a total length of 446 mm, and 40 tubing turns. There are two condensers on both outer sides and one evaporator in the middle of the OHPs. Thermal performance tests are conducted at various operating temperatures and heat rates. The working fluid fill ratio is varied. A high-performance OHP with FC-72 has been indicated for the first time. The FC-72 OHP can transport a 2040-W heat rate without dryout. The gravitational acceleration does not have a noticeable influence on the performance of the fluorocarbon OHP. The thermal performances of the fluorocarbon OHPs are compared with the case of an acetone OHP.
Mechanical Engineering, Combustion, Heat Transfer
Mechanical Engineering, Combustion, Heat Transfer
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 48 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |