doi: 10.2172/5277873
Underground Energy Storage (UES) Program activities during the period from April 1984 through March 1985 are briefly described. Primary activities in seasonal thermal energy storage (STES) involved field testing of high-temperature (>100/sup 0/C (212/sup 0/F)) aquifer thermal energy storage (ATES) at St. Paul, laboratory studies of geochemical issues associated with high-temperatures ATES, monitoring of chill ATES facilities in Tuscaloosa, and STES linked with solar energy collection. The scope of international activities in STES is briefly discussed.
Research Programs, Aquifers, Storage 250600* -- Energy Storage-- Thermal, 25 Energy Storage, Underground Storage, Energy Storage, Heat Storage, Seasonal Thermal Energy Storage
Research Programs, Aquifers, Storage 250600* -- Energy Storage-- Thermal, 25 Energy Storage, Underground Storage, Energy Storage, Heat Storage, Seasonal Thermal Energy Storage