Тема выпуÑкной квалификационной работы: «Повышение динамичеÑкой уÑтойчивоÑти ÑнергоÑиÑтем на оÑнове ÑƒÐ¿Ñ€Ð°Ð²Ð»ÐµÐ½Ð¸Ñ Ð¿Ð¾ данным ÑиÑтемы мониторинга переходных режимов». ОÑновной целью работы ÑвлÑетÑÑ Ð¾Ð±Ð¾Ñнование возможноÑти Ð¿Ñ€Ð¸Ð¼ÐµÐ½ÐµÐ½Ð¸Ñ Ð´Ð¾Ð¿Ð¾Ð»Ð½Ð¸Ñ‚ÐµÐ»ÑŒÐ½Ð¾Ð³Ð¾ Ñ€ÐµÐ³ÑƒÐ»Ð¸Ñ€Ð¾Ð²Ð°Ð½Ð¸Ñ Ð½Ð°Ð¿Ñ€ÑÐ¶ÐµÐ½Ð¸Ñ Ð¸ чаÑтоты Ñинхронных генераторов ÑлектричеÑких Ñтанций по данным ÑиÑтем мониторинга переходных режимов при управлении ÑлектроÑнергетичеÑкой ÑиÑтемой (ÐÐС) Ð´Ð»Ñ Ð¿Ð¾Ð²Ñ‹ÑˆÐµÐ½Ð¸Ñ ÑƒÑ€Ð¾Ð²Ð½Ñ ÑтатичеÑкой и динамичеÑкой уÑтойчивоÑти. Решаемые задачи: 1) разработка методики ÑовмеÑтной координации наÑтроек различных ÑиÑтем Ñ€ÐµÐ³ÑƒÐ»Ð¸Ñ€Ð¾Ð²Ð°Ð½Ð¸Ñ Ð´Ð»Ñ Ð¾Ð´Ð½Ð¾Ð²Ñ€ÐµÐ¼ÐµÐ½Ð½Ð¾Ð³Ð¾ Ð¿Ð¾Ð²Ñ‹ÑˆÐµÐ½Ð¸Ñ ÑƒÑ€Ð¾Ð²Ð½Ñ ÑтатичеÑкой и динамичеÑкой уÑтойчивоÑти; 2) оценка влиÑÐ½Ð¸Ñ Ð´Ð¾Ð¿Ð¾Ð»Ð½Ð¸Ñ‚ÐµÐ»ÑŒÐ½Ñ‹Ñ… обратных ÑвÑзей по разнице векторов напрÑжений в автоматичеÑких регулÑторах чаÑтоты и мощноÑти (ÐРЧМ) генераторов ÑлектричеÑких Ñтанций на динамичеÑкую уÑтойчивоÑть Ñ Ð¿Ð¾Ð¼Ð¾Ñ‰ÑŒÑŽ ÑовмеÑтного раÑчета переходных процеÑÑов и правила площадей; 3) повышение ÑƒÑ€Ð¾Ð²Ð½Ñ ÑтатичеÑкой уÑтойчивоÑть ÐÐС, как за Ñчет традиционных ÑредÑтв регулированиÑ, таких как автоматичеÑкие регулÑторы Ð²Ð¾Ð·Ð±ÑƒÐ¶Ð´ÐµÐ½Ð¸Ñ Ñильного дейÑÑ‚Ð²Ð¸Ñ (ÐÐ Ð’-СД), так Ñ Ð¿Ñ€Ð¸Ð¼ÐµÐ½ÐµÐ½Ð¸ÐµÐ¼ обратных ÑвÑзей по взаимным параметрам на оÑнове метода Ñдвига ÑобÑтвенных значений матрицы переменных ÑоÑтоÑниÑ. ИÑпользовалиÑÑŒ метод Ñдвига ÑобÑтвенных значений матрицы переменных ÑоÑтоÑÐ½Ð¸Ñ Ð¸ методика ÑовмеÑтного раÑчета переходных процеÑÑов на оÑнове чиÑленного Ð¸Ð½Ñ‚ÐµÐ³Ñ€Ð¸Ñ€Ð¾Ð²Ð°Ð½Ð¸Ñ ÑиÑтем алгебро-дифференциальных уравнений и правила площадей. Выполнено обоÑнование возможноÑти Ð¿Ñ€Ð¸Ð¼ÐµÐ½ÐµÐ½Ð¸Ñ Ð´Ð¾Ð¿Ð¾Ð»Ð½Ð¸Ñ‚ÐµÐ»ÑŒÐ½Ð¾Ð³Ð¾ Ñ€ÐµÐ³ÑƒÐ»Ð¸Ñ€Ð¾Ð²Ð°Ð½Ð¸Ñ Ð½Ð°Ð¿Ñ€ÑÐ¶ÐµÐ½Ð¸Ñ Ð¸ чаÑтоты Ñинхронных генераторов ÑлектричеÑких Ñтанций по данным ÑиÑтем мониторинга переходных режимов при управлении концентрированной ÑлектроÑнергетичеÑкой ÑиÑтемой Ð´Ð»Ñ Ð¿Ð¾Ð²Ñ‹ÑˆÐµÐ½Ð¸Ñ ÑƒÑ€Ð¾Ð²Ð½Ñ ÑтатичеÑкой и динамичеÑкой уÑтойчивоÑти в теÑтовых 14ти и 39ти узловых моделÑÑ… IEEE. Были определены оптимальные наÑтройки дополнительных обратных ÑвÑзей автоматичеÑких регулÑторов Ð²Ð¾Ð·Ð±ÑƒÐ¶Ð´ÐµÐ½Ð¸Ñ Ð¸ чаÑтоты Ð´Ð»Ñ Ð¿Ð¾Ð²Ñ‹ÑˆÐµÐ½Ð¸Ñ ÑƒÑ€Ð¾Ð²Ð½Ñ ÐºÐ°Ðº ÑтатичеÑкой, так и динамичеÑкой уÑтойчивоÑти ÑиÑтемы. При Ñтом показатели ÑтатичеÑкой уÑтойчивоÑти повышены более чем в 2 раза, а динамичеÑкой – на 45 %. Таким образом, обоÑнована возможноÑть Ð¿Ñ€Ð¸Ð¼ÐµÐ½ÐµÐ½Ð¸Ñ Ñ€ÐµÐ³ÑƒÐ»Ð¸Ñ€Ð¾Ð²Ð°Ð½Ð¸Ñ Ð¿Ð¾ взаимным параметрам, Ð´Ð»Ñ Ð¿Ð¾Ð²Ñ‹ÑˆÐµÐ½Ð¸Ñ ÐºÐ°Ðº ÑтатичеÑкой, так и динамичеÑкой уÑтойчивоÑти.
The topic of master thesis is “Improving transient stability based on implementation of wide area measurement system dataâ€. The main purpose of study is to substantiate the possibility of using additional voltage and frequency control of synchronous generators of power plants according to the wide area measurement system data in electric power system (EPS) to increase the level of small-signal and transient stability. Tasks to be solved: 1) development of methodology for joint coordination of various control system settings to increase the level of small-signal and transient stability; 2) assessment of additional phasor difference feedback impact in automatic frequency and power control systems (AFC) of power plant generators on stability using combined calculation of transients and extended equal area criterion; 3) increasing the level of EPS small-signal stability, both due to traditional scheme, such automatic voltage regulators and power system stabilizer (AVR+PSS), and using mutual parameter feedbacks based on the method of shifting eigenvalues of state variable matrix. The prospects for applying additional voltage and frequency control of power plant synchronous generators according to wide area measurement data in concentrated EPS for increasing the level of steady-state and transient stability in test 14 and 39 bus models of IEEE is carried out. Based on combined application of eigenvalue / equal area (mutual acceleration of synchronous machine rotors) shift approaches, the optimal settings of additional control feedbacks have been determined to increase the level of both small-signal and transient stability of the system. Small-signal stability indices are increased by more than 2 times, and transient ones by 45%. Thus, the possibility of applying mutual parameter control to increase both small-signal and transient stability is substantiated.
динамиÑеÑÐºÐ°Ñ ÑÑÑойÑивоÑÑÑ, transient stability, авÑомаÑиÑеÑкий ÑегÑлÑÑÐ¾Ñ Ð²Ð¾Ð·Ð±ÑждениÑ, ÑиÑÑема мониÑоÑинга пеÑÐµÑ Ð¾Ð´Ð½ÑÑ Ñежимов, ÑÑаÑиÑеÑÐºÐ°Ñ ÑÑÑойÑивоÑÑÑ, ÑÐ¸Ð½Ñ ÑоннÑй генеÑаÑоÑ, automatic voltage regulator, авÑомаÑиÑеÑкий ÑегÑлÑÑÐ¾Ñ ÑаÑÑоÑÑ Ð¸ моÑноÑÑи, automatic frequency control, synchronous generator, power system stabilizer, steady-state stability, wide area measurement system
динамиÑеÑÐºÐ°Ñ ÑÑÑойÑивоÑÑÑ, transient stability, авÑомаÑиÑеÑкий ÑегÑлÑÑÐ¾Ñ Ð²Ð¾Ð·Ð±ÑждениÑ, ÑиÑÑема мониÑоÑинга пеÑÐµÑ Ð¾Ð´Ð½ÑÑ Ñежимов, ÑÑаÑиÑеÑÐºÐ°Ñ ÑÑÑойÑивоÑÑÑ, ÑÐ¸Ð½Ñ ÑоннÑй генеÑаÑоÑ, automatic voltage regulator, авÑомаÑиÑеÑкий ÑегÑлÑÑÐ¾Ñ ÑаÑÑоÑÑ Ð¸ моÑноÑÑи, automatic frequency control, synchronous generator, power system stabilizer, steady-state stability, wide area measurement system
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |