doi: 10.1557/opl.2011.622
ABSTRACTA magnetic refrigeration test was performed using a test device filled with spherical GdN material synthesized by the hot isostatic pressing (HIP) method. Refrigeration with an active magnetic regenerator cycle was tested in the temperature range between 48 and 66 K, with the field changing from 1.2 to 3.7 T and 2.0 to 4.0 T at upper and lower sides of the regenerator bed filled with the GdN spheres, respectively. Temperature spans about of 2 K were obtained at both sides, and the total temperature span in each cycle attained about 5 K. The specific heat of the material was measured to calculate the magnetic entropy change ΔS and the adiabatic temperature change ΔT induced by the magnetic field change ΔH. It was suggested that for a given ΔH, larger ΔS and ΔT can be exploited when demagnetized to lower H, especially, to zero field.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |