Thermal insulation gypsum plaster was prepared from flue gas desulphurization (FGD) gypsum. K12 is more recommendable as foaming agent, when the mass fraction of K12 is around 0.1%, the setting time and compressive strength meet the requirements of gypsum-based construction materials. In the meanwhile, the thermal conductivity is 0.18W m–1 K–1, which can be used as a thermal insulation material. The hemihydrate mixtures obtained, allow the design of a new wall structure, which is more efficient as a thermal insulation system. The wall heat transfer coefficient test was carried out to compare thermal performance of two different thermal insulation systems. Compared with the thermal performance of a conventional system, the heat transfer coefficient of the new system was reduced by 5.6%. Finally, energy-saving analysis of a building was carried out to compare the energy-saving effect of the conventional and new systems of building. The energy-savings of the building with the new system increased by almost 2%, thus resulting in low energy consumption of the building.
Toplinskoizolacijska gipsana žbuka izrađena je od gipsa nastalog odsumporavanjem dimnog plina (FGD). Uz maseni udjel sredstva za pjenjenje (K12) 0,1% toplinska provodnost iznosi 0,18W m–1 K–1 pa se materijal može upotrijebiti za toplinsku izolaciju. Žbuka i sredstvo za pjenjenje uključeni su u novi tip zidne toplinske izolacije. Koeficijent prijenosa topline novog izolacijskog sustava određen je eksperimentalno i iznosi 0,608W m–2 K–1. Na temelju analize zaključeno je da se s novim sustavom ušteda energije u zgradi može popeti do 66,99%. Novi materijal može imati velik utjecaj na energijsku učinkovitost zgrade.
sredstvo za pjenjenje, gips nastao odsumporavanjem dimnog plina, toplinska izolacija, heat insulation system, heat transfer coefficient, FGD gypsum, Chemistry, energijska (energetska) učinkovitost, foaming agent, koeficijent prijenosa topline, QD1-999, energy efficiency
sredstvo za pjenjenje, gips nastao odsumporavanjem dimnog plina, toplinska izolacija, heat insulation system, heat transfer coefficient, FGD gypsum, Chemistry, energijska (energetska) učinkovitost, foaming agent, koeficijent prijenosa topline, QD1-999, energy efficiency
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 7 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |