doi: 10.13182/nt89-a34307
This paper reports the capability to depressurize a three-loop pressurized water reactor during a station blackout sequence assessed using the SCDAP/RELAP5 computer code. During the initial calculations, failure of the pressurizer surge line from creep rupture was predicted prior to relocation of molten core material to the lower plenum. The system response from that pressure boundary failure was then simulated until the accumulators emptied. Additional calculations assessed the accident progression in the even that the surge line did not fail. These calculations were intended to bound in-core damage progression prior to relocation of molten material to the lower plenum.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 2 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |