doi: 10.1117/12.930201
VIIRS thermal emissive bands (TEB) calibration data (blackbody and space counts) have been analyzed. The analysis results indicate that the Visible Infrared Imaging Radiometer Suite (VIIRS) TEB is stable and exceeds the specification. VIIRS Blackbody temperature is stable, too. The 6 platinum resistance thermometers (PRT) are also stable, except for the 3rd and 6th PRT have a periodic variation of 50 mK. Using the calibration data during the Blackbody temperature cool down and warm up, we found that noise equivalent deviation of temperatures (NEdT) varies with the Blackbody temperature. We developed a model that can predict the scene temperature dependent NEdT for the VIIRS M15 band. Comparisons between the VIIRS and other sensors such as AVHRR, MODIS and CrIS demonstrated that VIIRS TEB agrees generally with those sensors.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 2 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |