AbstractDespite their propensity for significant infectious and mechanical complications, tunneled central venous catheters (CVCs) have become a common means of vascular access in the world for patients requiring chronic hemodialysis for end‐stage renal disease. The objective of this study was to explore if cryopreserved solutions of the thrombolytic agent alteplase could be used as an effective, safe, and economically reasonable alternative in hemodialysis patients with occluded tunneled CVC. Patients requiring chronic hemodialysis and presenting with occluded tunneled CVC received a sufficient volume of the alteplase solution to fill the occluded catheter. To make alteplase economically feasible, it was diluted to 1‐mg/mL aliquots and they were stored at −20°C until use. Eighty‐one patients accounting for 179 attempted clearances were assessable for efficacy. One hundred forty‐seven (82.1%) of the 179 catheter clearance attempts resulted in successful catheter clearance after one dose. Twenty‐seven (15.1%) of all occluded CVCs were successful after two doses whereas five (2.8%) were not. No adverse events were reported. Cryopreserved 1‐mg/mL aliquots of alteplase are safe and effective in the clearance of occluded CVC for hemodialysis patients.
Male, Catheterization, Central Venous, Alteplase, Thrombosis, Middle Aged, Fibrinolytic Agents, Renal Dialysis, Hemodialysis, Tissue Plasminogen Activator, 616, Tunneled central venous catheter, Central Venous Catheters, Humans, Female, Prospective Studies, Vascular Patency, Aged
Male, Catheterization, Central Venous, Alteplase, Thrombosis, Middle Aged, Fibrinolytic Agents, Renal Dialysis, Hemodialysis, Tissue Plasminogen Activator, 616, Tunneled central venous catheter, Central Venous Catheters, Humans, Female, Prospective Studies, Vascular Patency, Aged
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 17 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |