This paper reports on the research and development of an optical current sensor for harmonic analysis within the electricity supply network. The device has a measurement capability, limited by the sampling frequency of the analog-to-digital converter, to around 20 kHz. We report on experimental verification of these measurements up to the 60th harmonic (3 kHz).
Electrical engineering. Electronics Nuclear engineering, 530, 620
Electrical engineering. Electronics Nuclear engineering, 530, 620
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 11 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |