The performance of the conventional predictive current control (PCC) when applied to a permanent-magnet brushless ac (PM BLAC) drive is analyzed. A technique is proposed to reduce the current errors that arise due to the inaccuracies in the system parameters and the nonideal behavior of the inverter during a steady-state operation. In addition, a current-regulated delta modulator is employed to achieve a fast dynamic response during a transient operation. The performance of the proposed PCC, which is simple to implement on a low-cost fixed-point DSP, is demonstrated experimentally
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 95 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |