A hydraulically actuated platform with 4-degrees of freedom (4-DOF) was designed to be able to apply velocity- or acceleration-controlled floor surface perturbations to freely walking human subjects. The apparatus was required to provide velocity-controlled translational perturbations over the floor surface, rotational perturbations about the ankle joint, and acceleration-controlled vertical translational perturbations. The apparatus was physically constructed, and tested by both measurements of dynamics and repeatability. Crossover of movement from one DOF to another was shown to be less than 1 mm or 0.5 degrees for all desired perturbations. Repeated perturbations were nearly identical with a standard deviation of less than 0.2 mm over translational axes. The application of the platform to human gait research was demonstrated with a protocol of midstance phase perturbations (n=8). For this, the platform controller was programmed to randomly select one out of three conditions: (1) no movement (control); (2) upward perturbation of 0.8 g, 50 mm, 300 ms after heel contact; (3) downward perturbation of 0.8 g, 50 mm, 300 ms after heel contact. In total, 90 trials (3 conditions x 30 repetitions) were recorded for each subject. By singling out the SOL EMG and normalizing and averaging over the subject population, it was shown that the upward and downward perturbations elicited at least two distinctive stereotypical reflex responses in the ankle extensors, opposite in sign. All subjects reported comfort with the apparatus and nobody fell.
Equipment Failure Analysis, Physical Stimulation, Transducers, Humans, Equipment Design, Robotics, Gait, Physical Examination, Locomotion, Biomechanical Phenomena
Equipment Failure Analysis, Physical Stimulation, Transducers, Humans, Equipment Design, Robotics, Gait, Physical Examination, Locomotion, Biomechanical Phenomena
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 39 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |