Several CLIC failure modes may cause beam loss at collimators between the linac and the collision point. Studying sample failures by computer simulation, we derive performance requirements for the CLIC collimation system. In particular, we discuss the effect of energy variations due to rf phase jitter, reduced current, or malfunction of one drive beam sector on the multi-bunch beam emittance.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |