Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Experience in Short Circuit Testing of LV Short Circuit Testing Transformer

Authors: N.S. Mohan Rao;

Experience in Short Circuit Testing of LV Short Circuit Testing Transformer

Abstract

For an On-line Short Circuit Facility, the main component of the facility is the Short Circuit Testing Transformer. There are no regular manufacturers of such transformers. Design of such transformers needs to be done taking into account many factors. The role of the manufacturer in getting the transformer designed for a particular application is very critical. Detailed checking the design calculations for various parameters including adequate design margins for heavy electromagnetic forces during short circuit, before commencement of manufacturing is very important. Such transformers are usually low impedance transformers and short circuit testing of such transformers to verify the design poses several problems, since the full-scale short circuit test means abnormally high electromagnetic forces, and may reduce the life of test transformer. It is debatable whether full-scale short circuit testing is necessary. Recently a Low Voltage short circuit test station was set up at Bangalore for an US multinational. Brief design features of the Test transformer and short circuit testing of the LV Short Circuit Transformer, decisions taken regarding full scale applicability of Short Circuit Tests with reasons thereof are enumerated in this paper.

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    1
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
1
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!