Several methods are proposed in literature to characterize the state of deterioration of water-treed cable insulation. One of these methods is the return voltage measurement (RVM) method, which was initially introduced as a diagnostic method for oil-paper insulating systems. It is mostly used to determine the condition of the paper insulation of transformer windings. It has been shown that it is possible to use RVM for detection of water trees in XLPE cables. In this paper, a methodology is presented that allows the detection of water trees in PE and XLPE insulated cables, without the need for a reference measurement. Also, the influence of temperature on RVM measurements was examined, for cables with and without water trees.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 7 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |