Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Computation of very fast transient overvoltages (VFTO) in a 1000 kV gas insulated substation

Authors: M. A. Haseeb; M. Joy Thomas;

Computation of very fast transient overvoltages (VFTO) in a 1000 kV gas insulated substation

Abstract

Very fast transient overvoltages (VFTO) generated in a gas insulated substation (GIS) during disconnector switching operations is one of the major concerns in insulation design of the GIS. Such over voltages can cause malfunctioning of the protection and control circuits in addition to initiating faults inside the gas insulated bus ducts of the substation especially in the presence of metallic particles. In this paper, VFTO have been estimated at various points in a 1000 kV rated substation for all possible valid disconnector switching operations. For the substation studied, the maximum computed overvoltage is 1.58 pu without considering the trapped charge on the busbar. Major frequency components in the simulated VFTO lies in the range of 840 KHz to 30 MHz. Simulations have been carried out using the Electromagnetic Transient Program (EMTP).

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    5
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
5
Top 10%
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!