A novel fully-differential capacitor measuring circuit is presented in this paper. Baseline drift is reduced by using a reference branch and the offsets of two op-amps are cancelled by each other. The simulation results show that linearity of this measuring circuit achieves 99.98%, baseline drift reduces to 4mV and sensitivity error between simulated result and theoretical calculated result is below 3%.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |