doi: 10.1109/7.256304 , 10.1109/7.256303
For pt.I, see ibid., vol.28, no.3, p.829-840 (1992). In the central-limit control (CLC), the multiloop controls are employed to regulate the output voltage and track the central weighted current, thus equalizing the output current of each converter module (CM). The current distribution error (CDE) between the output current of each CM is used as a criterion in judging system performance. The prediction and simulation results of this control scheme are illustrated. When incorporated with the maximum current limit, the proposed control method can determine the number of required converters in the active state for each load condition. As a result, the efficiency of a system can be increased significantly. A comparison between the performances of the system under master-slave control (MSC) and CLC is given. >
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 191 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 1% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 0.1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |