image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Diabetes Technology ...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
versions View all 2 versions
addClaim

A Review of Blood Glucose Monitor Accuracy

Authors: Fraya, King; David, Ahn; Victoria, Hsiao; Travis, Porco; David C, Klonoff;

A Review of Blood Glucose Monitor Accuracy

Abstract

The aim of this study was to assess the accuracy of blood glucose monitors (BGMs) from studies reported in the medical literature. A literature review was performed of publications between 2010 and 2017 that presented data about the accuracy of BGMs using ISO 15197 2003 and/or ISO 15197 2013 as target standards. We found 58 publications describing the performance of 143 unique BGM systems, 59 of which were Food and Drug Administration (FDA) cleared. When compared with non-FDA-cleared BGMs, FDA-cleared BGMs were significantly more likely to pass both ISO 15197 2003 (OR = 2.39, CI 1.45–3.92, P < 0.01) and ISO 15197 2013 standards (OR = 2.20, CI 1.51–3.27, P < 0.01). Newer meters were more likely to pass both ISO 15197 2003 and ISO 15197 2013 standards. Many of the studies were supported by BGM manufacturers, and when compared with independent studies, an FDA-cleared BGM was significantly more likely to pass in a manufacturer-supported study for both ISO 15197 2003 (OR = 22.4, CI 8.73–21.57, P < 0.001) and ISO 15197 2013 (OR = 23.08, CI 10.16–60.03, P < 0.001). BGM accuracy should be assessed independently following regulatory clearance to ensure accurate performance. Failure to meet performance levels mandated by standards can result in deleterious clinical and economic effects.

Keywords

Blood Glucose, United States Food and Drug Administration, Blood Glucose Self-Monitoring, Diabetes Mellitus, Humans, Reproducibility of Results, United States, Data Accuracy

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    33
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
33
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!