Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Consideration of signal to noise ratio for an imaging bolometer for ITER

Authors: Byron J. Peterson; Roger Reichle; Santosh Pandya; Martin G. O’Mullane; Kiyofumi Mukai;

Consideration of signal to noise ratio for an imaging bolometer for ITER

Abstract

An infrared imaging video bolometer (IRVB) is proposed for ITER having a tangential view of the entire ITER cross section. For the initial estimate of the signal level, a 840 m3 plasma is assumed to uniformly radiate 67.3 MW. A more detailed estimate of the signal strength is provided by synthetic images based on radiation data from SOLPS and SANCO models for the edge and core plasma, respectively. The Pt foil used as the radiation absorber would have the dimensions of 7 × 9 cm2 and a thickness of 16 μm that will stop 95% of the radiated power. Two different InSb based IR cameras having a sensitivity of 15 mK are considered for measuring the temperature rise of the foil due to the radiation. The first has 1280 × 1024 pixel2 and a frame rate of 105 fps. The second has 640 × 512 pixel2 and a frame rate of 1000 fps. The resulting IRVBs have 40 × 30 pixel2, 10 ms time resolution, and a signal to noise ratio (SNR) of 17 and 20 × 15 pixel2, 3 ms time resolution, and a SNR of 35, respectively. The synthetic image data give SNRs of 30 and 59, respectively.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    6
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
6
Top 10%
Average
Top 10%
hybrid