doi: 10.1063/1.3658366
The outdoor I‐V curve of a concentrating photovoltaic (CPV) Multi‐junction (MJ) module is affected by temperature, series resistance, electro‐optical mismatches among receivers mainly due to soiling effects, tracker misalignment and a particular spectral solar content. Starting from the previous works [1] and [2] and considering CPV MJ modules of only‐one string with series‐connected receivers, an original algorithm is developed to identify the photovoltaic current and the operating junction temperature of each receiver. Power losses due to the temperature, the series resistance and the electro‐optical mismatches can be separately identified as well.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |