image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao American Journal of ...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
American Journal of Kidney Diseases
Article . 2000 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Isothermic hemodialysis and ultrafiltration

Authors: L M, Rosales; D, Schneditz; A T, Morris; S, Rahmati; N W, Levin;

Isothermic hemodialysis and ultrafiltration

Abstract

The increase in patient temperature during hemodialysis is explained by hemodynamic compensation during ultrafiltration and hypovolemia that leads to peripheral vasoconstriction and reduced heat losses. We analyzed 51 stable high-efficiency hemodialysis treatments in 27 patients during isothermic dialysis in which body temperature was maintained at a constant level (+/-0.1 degrees C) using the temperature-control option of the Blood Temperature Monitor (BTM; Fresenius Medical Care, Bad Homburg, Germany). Hemodialysis was delivered using ultrapure water (limulus amebocyte lysate test < 0. 06 endotoxin units/mL) at mean blood flows of 410 +/- 40 mL/min. During treatments lasting 178 +/- 23 minutes, 4.8% +/- 1.4% of postdialysis body weight (W%) and 9.5% +/- 2.5% of postdialysis body water were removed using mean ultrafiltration rates of 1.1 +/- 0.3 L/h. Dialysate temperatures significantly decreased from 35.9 degrees C +/- 0.3 degrees C to 35.6 degrees C +/- 0.6 degrees C during hemodialysis. During these treatments, 187 +/- 69 kJ of thermal energy were removed from the patients through the extracorporeal circulation using cool dialysate. Extracorporeal heat flow was 17 +/- 6 W. Energy expenditure (H) estimated from anthropometric data was 65 +/- 12 W. Thus, 28% +/- 10% of estimated energy expenditure (H%) was removed during isothermic dialysis. A highly significant correlation was observed between H% and W% (H% = -5.6 * W%; r(2) = 0.91; P < 0.0001). This result is in support of the volume hypothesis of intradialytic heat accumulation and provides a rule of thumb to estimate extracorporeal cooling requirements for isothermic dialysis. Approximately 6% of H must be removed through the extracorporeal circulation for each percent of ultrafiltration-induced body-weight change. The importance of body temperature control during hemodialysis increases with increased ultrafiltration requirements.

Keywords

Male, Hot Temperature, Renal Dialysis, Body Weight, Temperature, Humans, Female, Middle Aged, Energy Metabolism, Body Temperature

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    71
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
71
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!