Step response of a governed hydrogenerator

Authors: T.R. Foord;

Step response of a governed hydrogenerator

Abstract

Stable control of the frequency in an electrical power system is essential to ensure continuity of supply. It is determined by the combined effect of the speed governors fitted to the generating sets throughout the system. The power output response of a steam-driven set to sudden loss in generating capacity is initially fast, but, after a few seconds, loss of boiler pressure reduces the output of the set. On the other hand, the response of a hydroelectric generator, although initially less rapid (due to the need to accelerate the water column), can be maintained at a high level for as long as storage water is available. Hydrosets are therefore particularly useful for system-frequency control provided they are fitted with governors that ensure a fast, but stable, response to a sudden change of load. In practice, governor settings are usually made during commissioning on the basis that the set will be stable when fully loaded and electrically isolated from the rest of the system. Attention, in the paper, is therefore given to the transient speed response of a single, isolated, governed hydrogenerator operating at, or near, full load.

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    6
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
6
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!