doi: 10.1049/cp.2010.0048
High-voltage DC-bus power quality is examined experimentally and by computer simulation during a short-circuit fault across the phase terminals of a five-phase, permanent magnet fault-tolerant generator. The DC-bus transients are seen to exceed the limits in MIL-STD-704F [1] and a control algorithm is proposed for a supercapacitor-based energy storage device that mitigates the transients. The controller performance is illustrated by computer simulations.
Supercapacitor energy storage, DC-bus power quality, Fault-tolerant generator
Supercapacitor energy storage, DC-bus power quality, Fault-tolerant generator
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 7 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |