
doi: 10.1038/oby.2006.199
pmid: 17062802
AbstractObjective: To compare estimates of total and truncal fatness from eight‐electrode bioelectrical impedance analysis equipment (BIA8) with those from DXA in centrally obese women. The secondary aim was to examine BMI and waist circumference (WC) as proxy measures for percentage total body fat (%TBF) and truncal body fat percentage (tr%BF).Research Methods and Procedures: This was a cross‐sectional study of 136 women (age, 48.1 ± 7.7 years; BMI, 30.4 ± 2.9 kg/m2; %TBFDXA, 46.0 ± 3.7%; WC, 104 ± 8 cm). Fatness was measured by DXA and Tanita BC‐418 equipment (Tanita Corp., Tokyo, Japan). Agreement among methods was assessed by Bland‐Altman plots, and regression analysis was used to evaluate anthropometric measures as proxies for total and abdominal fatness.Results: The percentage of overweight subjects was 41.9%, whereas 55.9% of the subjects were obese, as defined by BMI, and all subjects had a WC exceeding the World Health Organization cut‐off point for abdominal obesity. Compared with DXA, the BIA8 equipment significantly underestimated total %BF (−5.0; −3.6 to −8.5 [mean; 95% confidence interval]), fat mass (−3.6; −3.9 to −3.2), and tr%BF (−8.5; −9.1 to −7.9). The discrepancies between the methods increased with increasing adiposity for both %TBF and tr%BF (both p < 0.001). Variation in BMI explained 28% of the variation in %TBFDXA and 51% of %TBFBIA8. Using WC as a proxy for truncal adiposity, it explained only 18% of tr%BFDXA variance and 27% of tr%BFBIA8 variance. The corresponding figures for truncal fat mass were 49% and 35%, respectively. No significant age effects were observed in any of the regressions.Discussion: BIA8 underestimated both total and truncal fatness, compared with DXA, with higher dispersion for tr%BF than %TBF. The discrepancies increased with degree of adiposity, suggesting that the accuracy of BIA is negatively affected by obesity.
Adult, Waist-Hip Ratio, Abdominal Fat, Reproducibility of Results, Middle Aged, Body Mass Index, Absorptiometry, Photon, Cross-Sectional Studies, Body Composition, Electric Impedance, Humans, Female, Obesity, Adiposity, Aged
Adult, Waist-Hip Ratio, Abdominal Fat, Reproducibility of Results, Middle Aged, Body Mass Index, Absorptiometry, Photon, Cross-Sectional Studies, Body Composition, Electric Impedance, Humans, Female, Obesity, Adiposity, Aged
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 105 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
