Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao CJEMarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
CJEM
Article . 2020 . Peer-reviewed
License: Cambridge Core User Agreement
Data sources: Crossref
CJEM
Article . 2021
versions View all 2 versions
addClaim

Perceived versus actual cricothyroid membrane landmarking accuracy by emergency medicine residents and staff physicians

Authors: Nicholas Schouela; Michael Y. Woo; Andy Pan; Warren J. Cheung; Jeffery J. Perry;

Perceived versus actual cricothyroid membrane landmarking accuracy by emergency medicine residents and staff physicians

Abstract

ABSTRACTObjectivesCricothyrotomy is an intervention performed to salvage “can't intubate, can't ventilate” situations. Studies have shown poor accuracy with landmarking the cricothyroid membrane, particularly in female patients by surgeons and anesthesiologists. This study examines the perceived versus actual success rate of landmarking the cricothyroid membrane by resident and staff emergency physicians using obese and non-obese models.MethodsFive male and female volunteers were models. Each model was placed supine, and a point-of-care ultrasound expert landmarked the borders of each cricothyroid membrane; 20 residents and 15 staff emergency physicians were given one attempt to landmark five models. Overall accuracy and accuracy stratified by sex and obesity status were calculated.ResultsOverall landmarking accuracy amongst all participants was 58% (SD 18%). A difference in accuracy was found for obese males (88%) versus obese females (40%) (difference = 48%, 95% CI = 30–65%, p < 0.0001), and non-obese males (77%) versus non-obese females (46%) (difference = 31%, 95% CI = 12–51%, p = 0.004). There was no association between perceived difficulty and success (correlation = 0.07, 95% CI = −0.081–0.214, p = 0.37). Confidence levels overall were higher amongst staff physicians (3.0) than residents (2.7) (difference = 0.3, 95% CI = 0.1–0.6, p = 0.02), but there was no correlation between confidence in an attempt and its success (p = 0.33).ConclusionWe found that physicians demonstrate significantly lower accuracy when landmarking cricothyroid membranes of females. Emergency physicians were unable to predict their own accuracy while landmarking, which can potentially lead to increased failed attempts and a longer time to secure the airway. Improved training techniques may reduce failed attempts and improve the time to secure the airway.

Keywords

Male, Physicians, Emergency Medicine, Humans, Female, Clinical Competence, Cricoid Cartilage, Ultrasonography

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    2
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
2
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!