AbstractThe paper focuses on the analysis of thermo technical interaction of frame and glass systems in a selected type of window construction, which is currently an important factor of building design that concerns cold and moderate climates. The analysis was based on the laboratory experiment in a climate chamber with a hot box for particular combinations of frame and glass systems (see the appendix). The results show that easily applicable modifications of window constructions could improve their thermal performance. Some potential for further improvement window constructions is also obvious.
Window constructions, Glass system, Frame system, Engineering(all), Fenestration systems
Window constructions, Glass system, Frame system, Engineering(all), Fenestration systems
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |